Place of Origin: | China |
Brand Name: | oem |
Certification: | ce certificate |
Model Number: | omg09 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | usd2499/set |
Packaging Details: | 1set/carton |
Delivery Time: | 5-8 working days |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100sets/month |
Feature: | Wieght Loss And Body Shaping | Type: | Cryolipolysis Slimming Device |
---|---|---|---|
Function: | Body Slimming,weight Loss,Body Shaping | Warranty: | 1 Year |
Technology: | Cryo+Cavitation+RF | Voltage: | AC220V/50Hz AC110V/60Hz |
Keywords: | Cryolipolysis Machine | Cooling Temperature: | -10-10 Degree |
Service: | OEM ODM | Cavitation Frequency: | 40Khz |
High Light: | 360 Degree multifunction cryolipolysis machine,RF Cavitation multifunction cryolipolysis machine,Lipo 360 cryolipolysis machine |
360 Degree Surrounding Slimming Machine Lipo Fat Freezing Rf Cavitation Machine
What is 360 cryolipolysis?
cryolipolysis 360-degree full range of cooling and heating, freezing at minus 10℃ to positive 45℃ heating, 4 groups cycle modes for operation, parameters can be set flexibly; 8 pcs different sizes cryo handles are suitable for different size areas and body shape.
Independent power supply control operating system, running more stable and safer;Intelligent identification of the induction socket, insert the wrong accessories automatically alarm prompts to avoid mistake;The freezing head is made of soft silicone material, and the experience is more comfortable;After the cooling system starts or stops, it will automatically circulate water for 1 minute to ensure cooling and Heat dissipation; Real-time environmental dynamic temperature control monitoring under the working condition of the freezing head;The refrigeration module adopts the frost-proof safety module and automatically thermostats;The water cooling module uses a high-flow water pump to ensure that the water cooling efficiency The water pipeline adopts a series system. When the water circulation is abnormal, it can automatically stop working to ensure safe operation.
The order of use cryolipolysis: freeze head first, then cold laser pads, next day cavitation, radio frequency head, cold laser plate.
Course of treatment of cryolipolysis: about 3-6 times a course of treatment
The cryo head is mainly to metabolize the frozen fat to achieve a slimming effect. The main effect in the early stage is that 40K RF has the effect of firming, shaping and reducing size. The weight loss is mainly due to the metabolism of frozen fat. It is usually about a month for good metabolism, and it is usually about 1-3 months for poor metabolism. In the early stage, it is obvious that 40K and RF are used together well.
During the use of the freezing head, the customer feels that the suction is very tight, and the negative pressure air valve can be reduced or the suction time can be shortened.
Suction adjustment of cryolipolysis head:
For example:
Inhale 1.5
Deflate 0.5
Inhale 2.5
deflate 1.0
Inhale 3.5
Deflate about 1.0-1.5
Cold laser pads, no heat, mainly accelerates fat metabolism in the body through infrared laser. Can be used with cryohead or after 40K RF operation. At least 30 minutes for each part. The cycle can be arbitrarily matched.
40K RF cycle is used once a week in the early stage and once a half month in the later stage. Each probe is about 15-30 minutes each time.
The cycle of the freezing head: in the early stage, it can be used once in 20 days, and in the later stage, it can be used for a second time in a month. The duration of each part should not be too long to prevent frostbite epidermal skin
Do not use 40K and RF after operating the freezing head today because it is not good to use cold and hot on the same day, it is better to use the next day. Use 40K and RF and cold laser boards the next day.
Generally, the freezing head is operated first on the first day, and then the laser plate is cooled. Before operating the freezing head, a freezing film must be attached. After the adsorption part of a freezing head is adsorbed for about 3-5 minutes, the part should be moved. If the fat thickness is thicker, the temperature is adjusted downward, and the temperature of thinner fat is adjusted upward), and the other needs to be adjusted according to the weather. If it is hot, it can be adjusted to below zero degrees, and it should not exceed minus 4 degrees. Half an hour for each accessory
If you want customers to see obvious results, you can do it a little longer, and then the energy is high, but it also depends on the acceptance of the customer's energy
The time is calculated according to each part, not the whole body operation time. Anyway, each part of the fat blasting and radio frequency head is at least 15 minutes. If you want better results, you can slightly increase the time and energy, and you have to rely on Operation method to make the curve.
40K RF cycle: use once a week in the early stage and once a half month in the later stage. Each probe is about 15-30 minutes each time
The cycle of the freezing head: in the early stage, it can be used once in a short period of 20 days, and in the later stage, it can be used for a second time in a month. The duration of each part should not be too long to prevent frostbite epidermal skin.
Contact Person: Aissa
Tel: +8613131121185