Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine

Basic Information
Place of Origin: Jiangsu, China
Brand Name: ROTEC
Certification: CE ISO13485 KFDA
Model Number: TELLOS
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Standard Export Package
Delivery Time: 7-10 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 Units per month
Type: IPL IPL+ RF: No
Feature: Hair Removal, Blood Vessels Removal, Pore Remover, Pigment Removal, Pigmentation Correctors, Skin Tightening, Acne Treatment, Skin Rejuvenation Wavelength: 480nm 530nm 560nm 590nm 640nm
Spot Size: 10*40mm2 Energy: 1-50J/cm*cm
High Light:

opt shr machine

,

opt hair removal machine

 

 

Working priciple

IPL (Intense Pulsed Light) is a kind of light with high energy and broad wavelength, within the range from 400nm--1200nm. According to the principle of IPL photorejuvenation technology, intense pulsed light with broad spectrum affects pigmentations, broken capillary vessels and hair follicles.

IPL can treat pigmented lesions with rapid recovery. Dyschromia can be cleared after repeated sessions. Photoaging treatment has been explored. A series of IPL can be used for facial rejuvenation, improving skin laxity and collagen production.

 

OPT is with new AFT technology (Advanced Fluorescence Technology) uses low and equal energy.

OPT using the cutting-edge intense pulsed light technology, belongs to the fourth generation of photonic technology,perfect OPT (Optimal Pulse Technology) core technology, the use of three dimensional technology concepts: energy + Pulse Width + pulse waveform. Due to changes the pattern of treatment light output, OPT is a revolutionary in the development, not only improve the efficiency greatly but also safety.

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 0

  1. IPL solves the problem of telangiectasia

For the 560 or 580 nm treatment head, the major part of the energy is concentrated in the range of 560-800 nm.

that Oxyhemoglobin in capillaries absorption is better.

The IPL of 560 or 580 nm can penetrate the skin into dermis layer, and is preferentially absorbed by the water and

capillaries in the tissue, The heat can coagulate the blood in the capillaries without destroying the normal skin tissue;

After hemoglobin absorbs photons, the temperature rises, and heat is transferred to the blood vessel wall, thereby

destroying the endothelial cells of the blood vessel.

After the blood vessel is destroyed, it is metabolized by the tissue

 

Do not use Wavelength of 640nm treatment head.

After treatment, the skin became dark, and then turns to dark purple,finally to light grayish discoloration.

 

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 1

 

 

Application

1. Permanent hair removal
2. Skin Rejuvenation
3. Superficial pigmentation removal
4. Superficial vascular lesion removal
5. Acne reduction

 

 

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 2

Features

  1. Most advanced technology: SHR IPL;
  2. Suitable for all skin types treatment;
  3. Alarm protection system of water current and water temperature;
  4. Easier operation: 8 inch color touch screen, 18 settings memory systems, 16 languages;
  5. Easier installation: Plug-and-play CPC connectors;
  6. Longer working time: powerful cooling system (air + water );

Product Photo

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 3

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 4Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 5Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 6

 

Customer Feedback

Optimal Pulsed Light OPT Beauty Machine Blood Vessels RemovaL 640-1200nm Multifunction Machine 7

 

Daily Maintenance

 

1. The equipment is mainly composed of precise optical or electronic instruments, so its maintenance should be in accordance with their general rules.

 

2. Lest the energy should decline, please change the water in water tank every 3000 shots.

 

3. It’s forbidden to use alcohol or other inflammable to clean or disinfect the treatment head.

 

4. Use cleanser essence and clean cloth instead of the substance with strong acidity or alkalinity to clean the surface of this beauty apparatus.

 

5. Generally, this machine should be cleaned and

 

6..Please turn off the machine and disconnect power supply before maintenance.

 

7. Make sure not to let water or other liquid infiltrate inside the machine or hand piece during maintenance.

 

8. After each operation, clean the treatment head and put it back to the original place.

 

9. It’s forbidden to wipe this medical beauty equipment with chemicals.

 

10. Take the handle instead of any other places. Bringing the output line up at random may cause the looseness of internal connector and lead to short circuit.

 

Contact Details
peter

WhatsApp : +008618260407856