Durable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE Approved

Basic Information
Place of Origin: China
Brand Name: ROTEC
Certification: ISO13485 CE KFDA
Model Number: TELLOS
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Standard Export Package
Delivery Time: 7-10 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 Units per month
Contact Now

 
What does IPL work?
The technology uses a high-powered, hand-held, computer-controlled flashgun to deliver an intense, visible, broad-spectrum pulse of light, generally in the visible spectral range of 400 to 1200 nm.
Various cutoff filters are commonly used to selectively filter out shorter wavelengths, especially potentially damaging ultra violet light.
The resulting light has a spectral range that targets specific structures and chromophores (e.g. melanin in hair, or oxyhemoglobin in blood vessels) that are heated to destruction and reabsorbed by the body.
IPL shares some similarities with laser treatments, in that they both use light to heat and destroy their targets.
But unlike lasers that use a single wavelength (color) of light which typically matches only one chromophore and hence only treats one condition,
IPL uses a broad spectrum that when used with interchangeable filters, allows it to be used against several conditions.
This can be achieved when the IPL technician selects the appropriate filter that matches a specific chromophore.
 
Durable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE Approved
Technical Parameters

Wave Length

    480nm 530nm
560nm 590nm 640nm

Energy

1-50 J/cm2

Frequency

1 HZ

Input Power

600W

Power Source:

Pure Sapphire

Lamp

UK lamp, guarantee 1000,000 shots

Spot Size

15*50 mm

Cooling Temperature

Max -10 degree

Cooling System

Watering Coolig + Air cooling + Semi Conductor cooling

 

Mainly Application 
 

 
Eliminate the red blood vessels: Vascular issue, skin inflamentation, telangiectasia,(560nm 590nm)
 
Hyperpigmentation: Treatment of pigmentation, senile plaque, freckles,(530nm 560nm)
 
Skin rejuvenation:Make the skin texture smoother, more delicate and youger,(560nm 590nm)
 
Acne: Killig acne bacteria and treating acne,(480nm)
Control oil secretion: Shrink pore and inhibit sebaceous gland secretion(560nm 590nm)
 
Hair Removal: Heating melanin around the dermal papilla and destroying the hair follicle,(640nm)
 
Wrinkle removal: Lifting, anti-allergy:560nm 590nm 640nm
Desalination of acne pits and acne mark: 530 560nm
 

Hair Removal Treatment Procedure :


1. Beautician is required to offer consultation to the patient before treatment.
2. Shave unwanted hair before treatment.
3. Clean skin to remove cosmetics and sunscreens...etc.
4. Apply 1-2 mm cooling gel on the entire treatment area.
5. Operator and patient should wear glasses and goggles properly.
6. Set proper parameters according to patient's Skin Type, Hair Color, Hair Density.
7. Verify that the handpiece tip is cold, sliding handpiece to cool down the treatment area.
8. Click 'Ready' to start treatment and ensure the handpiece perpendicularly and tightly contact the treatment area during treatment.
9. Adjust the parameters during treatment according to patient’s feeling.
 
Clinical Endpoints:


• Follicle erythema and oedema, this endpoint typically appears a few minutes after the laser passage and this immediate skin response gives evidence of the effectiveness of the treatment.
• The pigmented hairs vaporise releasing a typical smell of smoke due to the burnt keratin.
 
Tellos Details


Durable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE Approved
Durable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE ApprovedDurable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE Approved
Durable IPL Beauty Machine OPT For Hair Removal Skin Rejuvenation Tellos CE Approved
 
Daily Maintenance
1. The equipment is mainly composed of precise optical or electronic instruments, so its maintenance should be in accordance with their general rules.
2. Lest the energy should decline, please change the water in water tank every 3000 shots.
3. It’s forbidden to use alcohol or other inflammable to clean or disinfect the treatment head.
4. Use cleanser essence and clean cloth instead of the substance with strong acidity or alkalinity to clean the surface of this beauty apparatus.
5. Generally, this machine should be cleaned and
6. Please turn off the machine and disconnect power supply before maintenance.
7. Make sure not to let water or other liquid infiltrate inside the machine or hand piece during maintenance.
8. After each operation, clean the treatment head and put it back to the original place.
9. It’s forbidden to wipe this medical beauty equipment with chemicals.
10. Take the handle instead of any other places. Bringing the output line up at random may cause the looseness of internal connector and lead to short circuit.
 
FAQ
 
1. The power of OPT is 600W, but the market is mostly 2000W power, is it your energy lower than market?
My company's OPT is really 600W, you can check it in the corresponding parameters of laser power supply. In fact, the market propaganda of 2000w is false, most of them just have 600W-800W energy. Cause our R & D staff tested other peer products through the professional energy meter comparison. Meanwhile, Our products are tested by clients through the professional energy meter comparison in Italy exhibition, and confirm the high energy.

 

2. What is the spot size of the handle? There are 15*50mm oversize spots on the market.
Hair removal handle spot is 50*15, it is true that in the market have larger spot. But if the power is constant, the spot is larger, the energy density is lower. What’s more, you can adjust OPT power 1 to 10HZ, use on-motion rapid sliding to treat, and the treatment efficiency is also very high.

 

3. Does the OPT instrument have several capacitors? Can I add a few more?
Now the configuration is two. According to the demand it can be increased, but we need ask engineer to confirm the host space.

 

4. Does the xenon lamp of the OPT be imported from foreign or come from China? What is the number of shots for the warranty?

Currently we adopted the best xenon lamp in China, it used for scientific research. The highest warranty is 500,000 times. At the same time, in order to looking for the best xenon lamp, we test the UK xenon lamp too. We can ensure that 500,000 times is under the range of energy attenuation.
 

5. Can I continue to use the instrument after more than 500,000 counts? How long can I use it?
Can be used, the need to provide a specific number of light, by my company engineers to calculate the relevant password. Machine input password, the machine can be unlocked.
Under normal circumstances, the handle can be used at least 50-80 million times, our customers have cleared, the use of 90 million -100 million times after the continued use, but the energy decay, and need to improve the level to achieve therapeutic effect.

 

6. OPT instrument handle why there is no filter? Is the filter form on the market?
Positioning for the hair removal handle, fixed spot, light output is more accurate.

 

7. Do you have 4s: IPL+RF+ND:YAG+E-light?
Sorry, we don’t have this machine at the moment. But our R&D has been researching this project this year.

Contact Details
peter

WhatsApp : 008618260407856